Control Delay Component

The Control Delay provides the capability of delaying control signals from 1 to 60 seconds. There is one Input, and up to 32 Outputs available.

Controls

The following Controls are available for each output.

Control

Function

Default/Range

Bypass

Bypasses the delay function for the associated channel. The Output is not delayed from Input.

Off/Bypassed

Delay

(Seconds)

Sets the delay time from the Input to the Output.

The maximum amount for all of the Delay channels is controlled by the Max Delay Property.

The Default for the controls increases from the first channel to the last in even increments based on the Max Delay and the Output Count Properties.

Range = 1 to 60

Properties

Property

Function

Choices

Output Count

Sets the number of outputs available.

1 to 32

Max Delay

(Seconds)

Sets the maximum amount of delay that can be applied from the Control Panel.

1 to 60

Control Pins

The following Control Pins are available for each output.

Pin Name

Value

String

Position

Pins Available

Bypass

0

1

no

bypassed

0

1

Output

Delay

0.000 to 0.100

0 ms to 100 s

0.000 to 1.00

Output

Related Topics Link IconRelated Topics


 

© 2009 - 2016 QSC, LLC. All rights reserved. QSC and the QSC logo are trademarks of QSC, LLC in the U.S. Patent and Trademark office and other countries. All other trademarks are the property of their respective owners.